Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Braz. J. Anesth. (Impr.) ; 73(1): 46-53, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1420655

RESUMO

Abstract Background Compound A is generated by sevoflurane when it reacts with carbon dioxide absorbers with strong bases at minimal fresh gas flow (FGF) and is nephrotoxic in animals. No conclusive data has shown increased risk in humans. The aim of this study was to investigate if minimal FGF promotes an increase in the incidence of acute kidney injury (AKI) when compared to high FGF in patients undergoing on-pump cardiac surgery under sevoflurane anesthesia. Methods Two hundred and four adult patients scheduled for on-pump cardiac surgery under sevoflurane anesthesia were randomly allocated to two groups differentiated by FGF: minimal FGF (0.5 L.min−1) or high FGF (2.0 L.min−1). Baseline creatinine measured before surgery was compared daily to values assayed on the first five postoperative days, and 24-hour urinary output was monitored, according to the KDIGO (Kidney Disease Improving Global Outcomes) guideline to define postoperative cardiac surgery-associated acute kidney injury (CSA-AKI). Creatinine measurements were also obtained 20 and 120 days after hospital discharge. Results Postoperative AKI occurred in 55 patients, 26 patients (29.5%) in the minimal FGF group and 29 patients (31.5%) in the high FGF group (p= 0.774). Twenty days after discharge, 11 patients (6.1%) still had CSA-AKI and 120 days after discharge only 2 patients (1.6%) still had CSA-AKI. Conclusions When compared to high FGF, minimal FGF sevoflurane anesthesia during on-pump cardiac surgery is not associated with increased risk of postoperative AKI in this population at high risk for renal injury.


Assuntos
Humanos , Adulto , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/epidemiologia , Procedimentos Cirúrgicos Cardíacos , Anestesia/efeitos adversos , Complicações Pós-Operatórias/induzido quimicamente , Complicações Pós-Operatórias/epidemiologia , Creatinina , Sevoflurano/efeitos adversos
2.
Braz J Anesthesiol ; 73(1): 46-53, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34852266

RESUMO

BACKGROUND: Compound A is generated by sevoflurane when it reacts with carbon dioxide absorbers with strong bases at minimal fresh gas flow (FGF) and is nephrotoxic in animals. No conclusive data has shown increased risk in humans. The aim of this study was to investigate if minimal FGF promotes an increase in the incidence of acute kidney injury (AKI) when compared to high FGF in patients undergoing on-pump cardiac surgery under sevoflurane anesthesia. METHODS: Two hundred and four adult patients scheduled for on-pump cardiac surgery under sevoflurane anesthesia were randomly allocated to two groups differentiated by FGF: minimal FGF (0.5 L.min-1) or high FGF (2.0 L.min-1). Baseline creatinine measured before surgery was compared daily to values assayed on the first five postoperative days, and 24-hour urinary output was monitored, according to the KDIGO (Kidney Disease Improving Global Outcomes) guideline to define postoperative cardiac surgery-associated acute kidney injury (CSA-AKI). Creatinine measurements were also obtained 20 and 120 days after hospital discharge. RESULTS: Postoperative AKI occurred in 55 patients, 26 patients (29.5%) in the minimal FGF group and 29 patients (31.5%) in the high FGF group (p = 0.774). Twenty days after discharge, 11 patients (6.1%) still had CSA-AKI and 120 days after discharge only 2 patients (1.6%) still had CSA-AKI. CONCLUSIONS: When compared to high FGF, minimal FGF sevoflurane anesthesia during on-pump cardiac surgery is not associated with increased risk of postoperative AKI in this population at high risk for renal injury.


Assuntos
Injúria Renal Aguda , Anestesia , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Sevoflurano/efeitos adversos , Creatinina , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/epidemiologia , Anestesia/efeitos adversos , Complicações Pós-Operatórias/induzido quimicamente , Complicações Pós-Operatórias/epidemiologia
3.
Braz. J. Anesth. (Impr.) ; 72(6): 711-719, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1420614

RESUMO

Abstract Background The influence of different crystalloid solutions infused during deceased-donor kidney transplant on the incidence of delayed graft function remains unclear. We investigated the influence of Plasma-Lyte® vs. 0.9% saline on the incidence of delayed graft function in deceased-donor kidney transplant recipients. Methods We conducted a single-blind randomized controlled trial of 104 patients aged 18 to 65 years who underwent deceased-donor kidney transplant under general anesthesia. Patients were randomly assigned to receive either Plasma-Lyte® (n = 52) or 0.9% saline (n = 52), at the same infusion volume, for intraoperative fluid replacement. The primary outcome was the occurrence of delayed graft function. Secondary outcomes included metabolic and electrolytic changes at the end of surgery. Results Two patients in the Plasma-Lyte® group and one in the 0.9% saline group died postoperatively and were not included for analysis. The incidence of delayed graft function in Plasma-Lyte® and 0.9% saline groups were 60.0% (95% Confidence Interval [95% CI 46.2-72.4]) and 74.5% (95% CI 61.1-84.4), respectively (p= 0.140). Mean (standard deviation) values of immediate postoperative pH and serum chloride levels in Plasma-Lyte® and 0.9% saline groups were 7.306 (0.071) and 7.273 (0.061) (p= 0.013), and 99.6 (4.2) mEq.L-1 and 103.3 (5.6) mEq.L-1, respectively (p< 0.001). All other postoperative metabolic and electrolyte variables were not statistically different at the immediate postoperative period (p> 0.05). Conclusion In deceased-donor kidney transplant recipients, the incidence of delayed graft function is not influenced by Plasma-Lyte® or 0.9% saline used for intraoperative fluid replacement.


Assuntos
Humanos , Transplante de Rim , Solução Salina , Método Simples-Cego , Eletrólitos , Função Retardada do Enxerto/prevenção & controle , Função Retardada do Enxerto/epidemiologia , Rim/fisiologia
4.
Braz J Anesthesiol ; 72(6): 711-719, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34563559

RESUMO

BACKGROUND: The influence of different crystalloid solutions infused during deceased-donor kidney transplant on the incidence of delayed graft function remains unclear. We investigated the influence of Plasma-Lyte.½ vs. 0.9% saline on the incidence of delayed graft function in deceased-donor kidney transplant recipients. METHODS: We conducted a single-blind randomized controlled trial of 104 patients aged 18 to 65 years who underwent deceased-donor kidney transplant under general anesthesia. Patients were randomly assigned to receive either Plasma-Lyte.½ (n.ß=.ß52) or 0.9% saline (n.ß=.ß52), at the same infusion volume, for intraoperative fluid replacement. The primary outcome was the occurrence of delayed graft function. Secondary outcomes included metabolic and electrolytic changes at the end of surgery. RESULTS: Two patients in the Plasma-Lyte.½ group and one in the 0.9% saline group died postoperatively and were not included for analysis. The incidence of delayed graft function in Plasma-Lyte.½ and 0.9% saline groups were 60.0% (95% Confidence Interval [95% CI 46.2...72.4]) and 74.5% (95% CI 61.1...84.4), respectively (p.ß=.ß0.140). Mean (standard deviation) values of immediate postoperative pH and serum chloride levels in Plasma-Lyte.½ and 0.9% saline groups were 7.306 (0.071) and 7.273 (0.061) (p.ß=.ß0.013), and 99.6 (4.2) mEq.L-1 and 103.3 (5.6) mEq.L-1, respectively (p.ß<.ß0.001). All other postoperative metabolic and electrolyte variables were not statistically different at the immediate postoperative period (p.ß>.ß0.05). CONCLUSION: In deceased-donor kidney transplant recipients, the incidence of delayed graft function is not influenced by Plasma-Lyte.½ or 0.9% saline used for intraoperative fluid replacement.


Assuntos
Transplante de Rim , Solução Salina , Humanos , Função Retardada do Enxerto/epidemiologia , Função Retardada do Enxerto/prevenção & controle , Método Simples-Cego , Eletrólitos , Rim/fisiologia
5.
Environ Mol Mutagen ; 62(2): 155-164, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33341964

RESUMO

Considering the importance and lack of data of toxicogenomic approaches on occupational exposure to anesthetics, we evaluated possible associations between waste anesthetic gases (WAGs) exposure and biological effects including oxidative stress, DNA damage, inflammation, and transcriptional modulation. The exposed group was constituted by anesthesia providers who were mainly exposed to the anesthetics sevoflurane and isoflurane (10 ppm) and to a lesser degree to nitrous oxide (150 ppm), and the control group was constituted by physicians who had no exposure to WAGs. The oxidative stress markers included oxidized DNA bases (comet assay), malondialdehyde (high-performance liquid chromatography [HPLC]), nitric oxide metabolites (ozone-chemiluminescence), and antioxidative markers, including individual antioxidants (HPLC) and antioxidant defense marker (ferric reducing antioxidant power by spectrophotometry). The inflammatory markers included high-sensitivity C-reactive protein (chemiluminescent immunoassay) and the proinflammatory interleukins IL-6, IL-8 and IL-17A (flow cytometry). Telomere length and gene expression related to DNA repair (hOGG1 and XRCC1), antioxidant defense (NRF2) and inflammation (IL6, IL8 and IL17A) were evaluated by real-time quantitative polymerase chain reaction. No significant differences (p > .0025) between the groups were observed for any parameter evaluated. Thus, under the conditions of the study, the findings suggest that occupational exposure to WAGs is not associated with oxidative stress or inflammation when evaluated in serum/plasma, with DNA damage evaluated in lymphocytes and leucocytes or with molecular modulation assessed in peripheral blood cells in university anesthesia providers. However, it is prudent to reduce WAGs exposure and to increase biomonitoring of all occupationally exposed professionals.


Assuntos
Anestesia/efeitos adversos , Anestésicos Inalatórios/efeitos adversos , Dano ao DNA/efeitos dos fármacos , Expressão Gênica/efeitos dos fármacos , Inflamação/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Estresse Oxidativo/efeitos dos fármacos , Adulto , Idoso , Poluentes Ocupacionais do Ar/efeitos adversos , Antioxidantes/metabolismo , Reparo do DNA/efeitos dos fármacos , Feminino , Hospitais , Humanos , Inflamação/metabolismo , Isoflurano/efeitos adversos , Masculino , Pessoa de Meia-Idade , Óxido Nitroso/efeitos adversos , Sevoflurano/efeitos adversos
6.
Braz J Anesthesiol ; 70(2): 82-89, 2020.
Artigo em Português | MEDLINE | ID: mdl-32475700

RESUMO

BACKGROUND AND OBJECTIVES: The perioperative cardiac arrest (CA) and mortality rates in Brazil, a developing country, are higher than in developed countries. The hypothesis of this review was that knowledge of the epidemiology of perioperative CA and mortality in Brazil enables the comparison with developed countries. The systematic review aimed to verify, in studies conducted in Brazil, the epidemiology of perioperative CA and mortality. METHOD AND RESULTS: A search strategy was carried out on different databases (PubMed, EMBASE, SciELO and LILACS) to identify observational studies that reported perioperative CA and/or mortality up to 48 hours postoperatively in Brazil. The primary outcomes were data on epidemiology of perioperative CA and mortality. In 8 Brazilian studies, there was a higher occurrence of perioperative CA and mortality in males; in extremes of age; in patients in worse physical status according to the American Society of Anesthesiologists (ASA); in emergency surgeries; in general anesthesia; and in cardiac, thoracic, vascular, abdominal and neurological surgeries. The patient's disease/condition was the main triggering factor, with sepsis and trauma as the main causes. CONCLUSIONS: The epidemiology of both perioperative CA and mortality events reported in Brazilian studies does not show important differences and, in general, is similar to studies in developed countries. However, sepsis represents one of the major causes of perioperative CA and mortality in Brazilian studies, contrasting with studies in developed countries in which sepsis is a secondary cause.


Assuntos
Parada Cardíaca/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Brasil/epidemiologia , Parada Cardíaca/mortalidade , Humanos , Complicações Pós-Operatórias/mortalidade
7.
Rev. bras. anestesiol ; 70(2): 82-89, Mar.-Apr. 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1137154

RESUMO

Abstract Background and objectives: The perioperative cardiac arrest (CA) and mortality rates in Brazil, a developing country, are higher than in developed countries. The hypothesis of this review was that knowledge of the epidemiology of perioperative CA and mortality in Brazil enables the comparison with developed countries. The systematic review aimed to verify, in studies conducted in Brazil, the epidemiology of perioperative CA and mortality. Method and results: A search strategy was carried out on different databases (PubMed, EMBASE, SciELO and LILACS) to identify observational studies that reported perioperative CA and/or mortality up to 48 hours postoperatively in Brazil. The primary outcomes were data on epidemiology of perioperative CA and mortality. In 8 Brazilian studies, there was a higher occurrence of perioperative CA and mortality in males; in extremes of age; in patients in worse physical status according to the American Society of Anesthesiologists (ASA); in emergency surgeries; in general anesthesia; and in cardiac, thoracic, vascular, abdominal and neurological surgeries. The patient's disease/condition was the main triggering factor, with sepsis and trauma as the main causes. Conclusions: The epidemiology of both perioperative CA and mortality events reported in Brazilian studies does not show important differences and, in general, is similar to studies in developed countries. However, sepsis represents one of the major causes of perioperative CA and mortality in Brazilian studies, contrasting with studies in developed countries in which sepsis is a secondary cause.


Resumo Justificativa e objetivos: As incidências de parada cardíaca (PC) e de mortalidade perioperatória no Brasil, um país em desenvolvimento, são mais elevadas em relação às dos países desenvolvidos. A hipótese desta revisão é que o conhecimento da epidemiologia de PC e de mortalidade perioperatória no Brasil possibilita sua comparação com a dos países desenvolvidos. A revisão sistemática teve como objetivo verificar, em estudos realizados no Brasil, a epidemiologia de PC e de mortalidade perioperatória. Conteúdo: Realizou-se estratégia de busca em diferentes bases de dados (PubMed, EMBASE, SciELO e LILACS) para a identificação de estudos observacionais que reportaram PC e/ou mortalidade perioperatória até 48 horas pós-operatório no Brasil. Os desfechos primários foram dados de epidemiologia de PC e de mortalidade perioperatória. Em 8 estudos nacionais, identificou- se maior ocorrência de PC e de mortalidade perioperatória no sexo masculino, em extremos de idade, em pacientes em pior estado físico segundo a American Society of Anesthesiologists (ASA), em cirurgias de emergência, em anestesia geral, e em cirurgias cardíaca, torácica, vascular, abdominal e neurológica. A doença/condição do paciente foi o principal fator desencadeante, tendo como causas principais a sepse e o trauma. Conclusões: Nos estudos nacionais, a epidemiologia dos eventos tanto de PC como de mortalidade perioperatória não apresenta diferenças importantes, e de maneira geral, é semelhante à de estudos de países desenvolvidos. Entretanto, a sepse, nos estudos nacionais, representa uma das principais causas de PC e de mortalidade perioperatória, diferenciando-se dos estudos de países desenvolvidos nos quais a sepse é causa secundária.


Assuntos
Humanos , Complicações Pós-Operatórias/epidemiologia , Parada Cardíaca/epidemiologia , Complicações Pós-Operatórias/mortalidade , Brasil/epidemiologia , Parada Cardíaca/mortalidade
8.
São Paulo med. j ; 136(2): 103-108, Mar.-Apr. 2018. tab
Artigo em Inglês | LILACS | ID: biblio-904147

RESUMO

ABSTRACT BACKGROUND: A high-quality electronic search is essential for ensuring accuracy and comprehensiveness among the records retrieved when conducting systematic reviews. Therefore, we aimed to identify the most efficient method for searching in both MEDLINE (through PubMed) and EMBASE, covering search terms with variant spellings, direct and indirect orders, and associations with MeSH and EMTREE terms (or lack thereof). DESIGN AND SETTING: Experimental study. UNESP, Brazil. METHODS: We selected and analyzed 37 search strategies that had specifically been developed for the field of anesthesiology. These search strategies were adapted in order to cover all potentially relevant search terms, with regard to variant spellings and direct and indirect orders, in the most efficient manner. RESULTS: When the strategies included variant spellings and direct and indirect orders, these adapted versions of the search strategies selected retrieved the same number of search results in MEDLINE (mean of 61.3%) and a higher number in EMBASE (mean of 63.9%) in the sample analyzed. The numbers of results retrieved through the searches analyzed here were not identical with and without associated use of MeSH and EMTREE terms. However, association of these terms from both controlled vocabularies retrieved a larger number of records than did the use of either one of them. CONCLUSIONS: In view of these results, we recommend that the search terms used should include both preferred and non-preferred terms (i.e. variant spellings and direct/indirect order of the same term) and associated MeSH and EMTREE terms, in order to develop highly-sensitive search strategies for systematic reviews.


Assuntos
Humanos , Descritores , Literatura de Revisão como Assunto , Armazenamento e Recuperação da Informação/métodos , Ferramenta de Busca/métodos , Anestesiologia , MEDLINE
9.
Sao Paulo Med J ; 136(2): 103-108, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29340504

RESUMO

BACKGROUND: A high-quality electronic search is essential for ensuring accuracy and comprehensiveness among the records retrieved when conducting systematic reviews. Therefore, we aimed to identify the most efficient method for searching in both MEDLINE (through PubMed) and EMBASE, covering search terms with variant spellings, direct and indirect orders, and associations with MeSH and EMTREE terms (or lack thereof). DESIGN AND SETTING: Experimental study. UNESP, Brazil. METHODS: We selected and analyzed 37 search strategies that had specifically been developed for the field of anesthesiology. These search strategies were adapted in order to cover all potentially relevant search terms, with regard to variant spellings and direct and indirect orders, in the most efficient manner. RESULTS: When the strategies included variant spellings and direct and indirect orders, these adapted versions of the search strategies selected retrieved the same number of search results in MEDLINE (mean of 61.3%) and a higher number in EMBASE (mean of 63.9%) in the sample analyzed. The numbers of results retrieved through the searches analyzed here were not identical with and without associated use of MeSH and EMTREE terms. However, association of these terms from both controlled vocabularies retrieved a larger number of records than did the use of either one of them. CONCLUSIONS: In view of these results, we recommend that the search terms used should include both preferred and non-preferred terms (i.e. variant spellings and direct/indirect order of the same term) and associated MeSH and EMTREE terms, in order to develop highly-sensitive search strategies for systematic reviews.


Assuntos
Anestesiologia , Armazenamento e Recuperação da Informação/métodos , Literatura de Revisão como Assunto , Ferramenta de Busca/métodos , Descritores , Humanos , MEDLINE
10.
Rev. bras. anestesiol ; 67(5): 516-520, Sept-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-897762

RESUMO

Abstract Background and objectives Occupational exposure to waste anesthetic gases in operating room without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhalational anesthetics isoflurane and sevoflurane in operating room with and without central scavenging system. Method Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120 min after the start of surgery) in both operating room types. Results All isoflurane and sevoflurane concentrations in unscavenged operating room were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged operating room, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. Conclusions The exposure to both anesthetics exceeded the international limit in unscavenged operating room. In scavenged operating room, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the operating room scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.


Resumo Justificativa e objetivos A exposição ocupacional aos resíduos de gases anestésicos em salas de operação (SO) sem sistema ativo de exaustão tem sido associada a efeitos adversos à saúde. Assim, o objetivo do estudo foi comparar os resíduos dos anestésicos inalatórios isoflurano e sevoflurano em SO com e sem sistema de exaustão. Método Concentrações residuais de isoflurano e sevoflurano foram mensuradas por analisador infravermelho em diferentes locais (próximo à área respiratória do auxiliar de enfermagem e do anestesiologista e próximo à estação de anestesia) e em dois momentos (30 e 120 min após o início da cirurgia) em ambos os tipos de SO. Resultados Todas as concentrações de isoflurano e sevoflurano nas SO sem sistema de exaustão foram mais elevadas em relação ao valor limite recomendado pelos EUA (2 partes por milhão), independentemente do local e momento avaliados. Nas SO com sistema de exaustão, as concentrações médias de isoflurano ficaram dentro do limite de exposição, exceto para as mensurações próximas à estação de anestesia, independentemente dos momentos avaliados. Para o sevoflurano, as concentrações excederam o valor limite em todos locais de medição e nos dois momentos. Conclusões A exposição a ambos os anestésicos excedeu o limite internacional nas SO sem sistema de exaustão. Nas SO com sistema de exaustão, as concentrações de sevoflurano, e em menor extensão, as de isoflurano excederam o valor limite recomendado. Dessa forma, o sistema de exaustão das SO analisado no presente estudo diminuiu as concentrações dos anestésicos, embora não tenha reduzido a valores internacionalmente recomendados.


Assuntos
Depuradores de Gases , Poluição do Ar em Ambientes Fechados/análise , Anestésicos Inalatórios/análise , Sevoflurano/análise , Isoflurano/análise , Salas Cirúrgicas , Brasil , Hospitais Universitários
11.
J Clin Anesth ; 40: 127-138, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28625437

RESUMO

STUDY OBJECTIVE: To compare the use of inhalation versus intravenous anaesthesia for adults undergoing on-pump or off-pump coronary artery bypass grafting. DESIGN: A systematic review. SETTING: A hospital-affiliated university. MEASUREMENTS: The following databases were searched: the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 10), MEDLINE, EMBASE, and LILACS (from inception to October 2016). We used the GRADE approach to rate overall certainty of the evidence. RESULTS: In total we included 58 studies with a total of 6105 participants. The methodological quality was difficult to assess as it was poorly reported in 35 included studies (three or more domains were rated as unclear risk of bias). Two trials of sevoflurane showed a statistically significant reduction in death within 180 to 365days of surgery (on-pump) (RR 4.10, 95% CI 1.42 to 11.79; p=0.009; I2=not applicable; high quality of evidence). There was also a statistically significant difference favouring sevoflurane compared to propofol on both inotropic (RR 2.11, 95% CI 1.53 to 2.90; p<0.00001; I2=0%) and vasoconstrictor support needed (RR 1.51, 95% CI 1.04 to 2.22; p=0.03; I2=0%) after coronary artery bypass grafting on-pump. Two trials of sevoflurane (MD -0.22, 95% CI -0.41 to -0.03; p=0.02; I2=0%) and two further trials of desflurane (MD -0.33, 95% CI -0.45 to -0.20; p<0.00001; I2=82%) showed a statistically significant difference on cardiac index during and after coronary artery bypass grafting on-pump, respectively. CONCLUSIONS: There is high quality evidence that sevoflurane reduces death within 180 to 365days of surgery and, inotropic and vasoconstrictor support compared to propofol for patients undergoing coronary artery bypass grafting. There is also some evidence showing that the cardiac index is minimally influenced by administration of sevoflurane and desflurane compared to propofol.


Assuntos
Anestesia por Inalação/métodos , Anestesia Intravenosa/métodos , Ponte de Artéria Coronária/métodos , Anestesia por Inalação/efeitos adversos , Anestesia Intravenosa/efeitos adversos , Anestésicos Inalatórios/efeitos adversos , Anestésicos Intravenosos/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Humanos , Éteres Metílicos/efeitos adversos , Propofol/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sevoflurano
12.
Anesth Analg ; 124(5): 1674-1677, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28431427

RESUMO

Intrathecal local anesthetic maldistribution is a well-known cause of spinal anesthesia failure (SAF). This could potentially result in sensory blockade restricted to the sacral dermatomes. We sought to determine the overall incidence of SAF and the role of sacral dermatomes in differentiating between total and partial failures. Of the 3111 spinals prospectively examined, 194 (6.2%) were classified as failures. Of the 72 presumed total failures based on the initial assessment, evaluation of the sacral dermatomes revealed sensory blockade in 32 (44%; 95% confidence interval, 32.7%-56.6%). Sacral dermatome assessment after SAF may be important in safely guiding subsequent anesthetic management.


Assuntos
Raquianestesia/efeitos adversos , Anestésicos Locais/efeitos adversos , Bupivacaína/efeitos adversos , Atividade Motora/efeitos dos fármacos , Sacro/efeitos dos fármacos , Limiar Sensorial/efeitos dos fármacos , Adulto , Anestésicos Locais/administração & dosagem , Bupivacaína/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exame Neurológico , Limiar da Dor/efeitos dos fármacos , Estudos Prospectivos , Sacro/fisiologia , Sensação Térmica/efeitos dos fármacos , Falha de Tratamento
13.
Rev Bras Anestesiol ; 67(5): 516-520, 2017.
Artigo em Português | MEDLINE | ID: mdl-28259354

RESUMO

BACKGROUND AND OBJECTIVES: Occupational exposure to waste anesthetic gases in operating room (OR) without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhaled anesthetics isoflurane and sevoflurane in OR with and without central scavenging system. METHOD: Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120minutes after the start of surgery) in both OR types. RESULTS: All isoflurane and sevoflurane concentrations in unscavenged OR were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged OR, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. CONCLUSIONS: The exposure to both anesthetics exceeded the international limit in unscavenged OR. In scavenged OR, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the OR scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Anestésicos Inalatórios/análise , Depuradores de Gases , Isoflurano/análise , Sevoflurano/análise , Brasil , Hospitais Universitários , Salas Cirúrgicas
14.
Acta Cir Bras ; 31(7): 434-41, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27487277

RESUMO

PURPOSE: To investigate changes in the serum concentration and renal expression of IL-1 and TNF-α cytokines in rats that received sevoflurane and glibenclamide prior to hemorrhage. METHODS: Two groups of sevoflurane-anesthetized Wistar rats (n=10): G1 (control) and G2 (glibenclamide, 1 µg/g i.v.); hemorrhage of 30% blood volume (10% every 10 min), with replacement using Ringer solution, 5 ml/kg/h. Serum concentrations of IL-1 and TNF-α were studied in the first hemorrhage (T1) and 50 min later (T2), renal expression, at T2. RESULTS: In serum, G1 TNF-α (pg/mL) was T1=178.6±33.5, T2=509.2±118.8 (p<0.05); IL-1 (pg/mL) was T1=148.8±31.3, T2=322.6±115.4 (p<0.05); in G2, TNF-α was T1=486.2±83.6, T2=261.8±79.5 (p<0.05); IL-1 was T1=347.0±72.0, T2= 327.3±90.9 (p>0.05). The expression of TNF-α and IL-1 in the glomerular and tubular cells was significantly higher in the G2 group. CONCLUSIONS: Hemorrhage and glibenclamide elevated TNF-α and IL-1 concentrations in serum and kidneys. High levels of TNF-α already present before the hemorrhage in the glibenclamide group may have attenuated the damages found in the kidneys after the ischemia event.


Assuntos
Glibureto/farmacologia , Hipoglicemiantes/farmacologia , Interleucina-1/metabolismo , Rim/efeitos dos fármacos , Choque Hemorrágico/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Anestésicos Inalatórios/administração & dosagem , Animais , Peso Corporal/efeitos dos fármacos , Canais KATP/antagonistas & inibidores , Rim/irrigação sanguínea , Rim/metabolismo , Túbulos Renais/efeitos dos fármacos , Túbulos Renais/metabolismo , Éteres Metílicos/administração & dosagem , Modelos Animais , Distribuição Aleatória , Ratos Wistar , Sevoflurano
15.
Acta cir. bras ; 31(7): 434-441, tab, graf
Artigo em Inglês | LILACS | ID: lil-787265

RESUMO

ABSTRACT PURPOSE: To investigate changes in the serum concentration and renal expression of IL-1 and TNF-α cytokines in rats that received sevoflurane and glibenclamide prior to hemorrhage. METHODS: Two groups of sevoflurane-anesthetized Wistar rats (n=10): G1 (control) and G2 (glibenclamide, 1 µg/g i.v.); hemorrhage of 30% blood volume (10% every 10 min), with replacement using Ringer solution, 5 ml/kg/h. Serum concentrations of IL-1 and TNF-α were studied in the first hemorrhage (T1) and 50 min later (T2), renal expression, at T2. RESULTS: In serum, G1 TNF-α (pg/mL) was T1=178.6±33.5, T2=509.2±118.8 (p<0.05); IL-1 (pg/mL) was T1=148.8±31.3, T2=322.6±115.4 (p<0.05); in G2, TNF-α was T1=486.2±83.6, T2=261.8±79.5 (p<0.05); IL-1 was T1=347.0±72.0, T2= 327.3±90.9 (p>0.05). The expression of TNF-α and IL-1 in the glomerular and tubular cells was significantly higher in the G2 group. CONCLUSIONS: Hemorrhage and glibenclamide elevated TNF-α and IL-1 concentrations in serum and kidneys. High levels of TNF-α already present before the hemorrhage in the glibenclamide group may have attenuated the damages found in the kidneys after the ischemia event.


Assuntos
Animais , Choque Hemorrágico/metabolismo , Interleucina-1/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Glibureto/farmacologia , Hipoglicemiantes/farmacologia , Rim/efeitos dos fármacos , Peso Corporal/efeitos dos fármacos , Distribuição Aleatória , Ratos Wistar , Anestésicos Inalatórios/administração & dosagem , Modelos Animais , Canais KATP/antagonistas & inibidores , Rim/irrigação sanguínea , Rim/metabolismo , Túbulos Renais/efeitos dos fármacos , Túbulos Renais/metabolismo , Éteres Metílicos/administração & dosagem
16.
Int J Pediatr Otorhinolaryngol ; 83: 63-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26968055

RESUMO

BACKGROUND AND OBJECTIVES: Pediatric airway management is a priority during anesthesia, critical care and emergency medicine. The purpose of this study is to validate bedside tests that predict airway management difficulty in anesthetized children. METHODS: Children under 12 years of age were recruited in a cross-sectional study to assess the value of some anthropometric measures as predictors of laryngoscopic difficulty. The patients were divided into three groups by age. Weight, height, neck circumference, BMI (body mass index), inter incisors distance thyromental distance, sternomental distance, frontal plane to chin distance (FPCD) and the Mallampati index were determined and were correlated with the CML (Cormack & Lehane classification). RESULTS: The incidence of difficult laryngoscopy (CML 3 or 4) was 3.58%. Factors that were significantly associated with laryngoscopic difficulty included short inter incisors distance, high FPCD, thyromental distance, sternomental distance and the Mallampati index. The FPCD/weight index exhibited a higher area under the ROC curve than any other variable considered. CONCLUSIONS: This study confirms that the FPCD and the FPCD/weight ratio are the most consistent predictors of laryngoscopic difficulty in pediatric patients. For patients over 6 months of age, the IID also correlated with laryngoscopic difficulty. For children who were capable of obeying simple orders, the Mallampati test correlated better with laryngoscopic difficulty than did the Mallampati test with phonation. Our results strongly suggest that skilled professionals should perform airway management in children, especially in patients with a high FPCD or a high FPCD/weight ratio.


Assuntos
Manuseio das Vias Aéreas/métodos , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Testes Imediatos , Anestesia/efeitos adversos , Anestesia/métodos , Índice de Massa Corporal , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Laringoscopia/efeitos adversos , Masculino , Curva ROC , Fatores de Risco
17.
Inflamm Res ; 64(12): 939-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26410399

RESUMO

INTRODUCTION: There is great concern about the possible harmful effects of exposure to volatile anesthetics. The current study aimed at evaluating, for the first time, the effects of occupational exposure to anesthetic gases on physicians who work in operating rooms, by determining several inflammatory cytokines. MATERIALS AND METHODS: Plasma inflammatory cytokines (IL-1ß, -6, -8, -10, -12, TNF-α) were investigated in 30 individuals who were allocated into two groups of 15: the exposed group, consisting of operating room medical personnel exposed to a mixture of anesthetic gases for 3 years, and a control group composed of medical personnel not exposed to anesthetic gases. The concentrations of volatile anesthetics were measured in the operating room by means of an infrared portable analyzer RESULTS AND CONCLUSIONS: Our findings suggest an increase of the pro-inflammatory IL-8 (p<0.05) in medical personnel exposed to high concentrations of anesthetic gases, even for a relatively short period.


Assuntos
Anestésicos Inalatórios/efeitos adversos , Citocinas/biossíntese , Inflamação/induzido quimicamente , Inflamação/metabolismo , Exposição Ocupacional/efeitos adversos , Adulto , Anestésicos Inalatórios/análise , Monitoramento Ambiental , Feminino , Humanos , Interleucina-8/biossíntese , Interleucinas/biossíntese , Isoflurano/efeitos adversos , Isoflurano/análise , Masculino , Éteres Metílicos/efeitos adversos , Éteres Metílicos/análise , Óxido Nitroso/efeitos adversos , Óxido Nitroso/análise , Salas Cirúrgicas , Sevoflurano , Fator de Necrose Tumoral alfa/biossíntese
18.
Clinics (Sao Paulo) ; 70(9): 618-22, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26375563

RESUMO

OBJECTIVE: We refer to the effectiveness (known as pragmatic or real world) and efficacy (known as explanatory or desired or ideal world) of interventions. However, these terms seem to be randomly chosen by investigators who design clinical trials and do not always reflect the true purpose of the study. A pragmatic-explanatory continuum indicator summary tool was thus developed with the aim of identifying the characteristics of clinical trials that distinguish between effectiveness and efficacy issues. We verified whether clinical trials used the criteria proposed by the indicator summary tool, and we categorized these clinical trials according to a new classification. METHOD: A systematic survey of randomized clinical trials was performed. We added a score ranging from 0 (more efficacious) to 10 (more effective) to each domain of the indicator summary tool and proposed the following classifications: high efficacy (<25), moderate efficacy (25-50), moderate effectiveness (51-75), and high effectiveness (<75). RESULTS: A total of 844 randomized trials were analyzed. No analyzed trials used the criteria proposed by the indicator summary tool. Approximately 44% of the trials were classified as having moderate effectiveness, and 43.82% were classified as having moderate efficacy. CONCLUSIONS: Most clinical trials used the term "efficacy" to illustrate the application of results in clinical practice, but the majority of those were classified as having moderate effectiveness according to our proposed score. The classification based on the 0-100 score is still highly subjective and can be easily misunderstood in all domains based on each investigator's own experiences and knowledge.


Assuntos
Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Resultado do Tratamento , Bibliometria , Ensaios Clínicos como Assunto/classificação , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto/classificação , Projetos de Pesquisa
19.
Clinics ; 70(9): 618-622, Sept. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-759287

RESUMO

OBJECTIVE:We refer to the effectiveness (known as pragmatic or real world) and efficacy (known as explanatory or desired or ideal world) of interventions. However, these terms seem to be randomly chosen by investigators who design clinical trials and do not always reflect the true purpose of the study. A pragmatic-explanatory continuum indicator summary tool was thus developed with the aim of identifying the characteristics of clinical trials that distinguish between effectiveness and efficacy issues. We verified whether clinical trials used the criteria proposed by the indicator summary tool, and we categorized these clinical trials according to a new classification.METHOD:A systematic survey of randomized clinical trials was performed. We added a score ranging from 0 (more efficacious) to 10 (more effective) to each domain of the indicator summary tool and proposed the following classifications: high efficacy (<25), moderate efficacy (25-50), moderate effectiveness (51-75), and high effectiveness (<75).RESULTS:A total of 844 randomized trials were analyzed. No analyzed trials used the criteria proposed by the indicator summary tool. Approximately 44% of the trials were classified as having moderate effectiveness, and 43.82% were classified as having moderate efficacy.CONCLUSIONS:Most clinical trials used the term “efficacy” to illustrate the application of results in clinical practice, but the majority of those were classified as having moderate effectiveness according to our proposed score. The classification based on the 0-100 score is still highly subjective and can be easily misunderstood in all domains based on each investigator’s own experiences and knowledge.


Assuntos
Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Resultado do Tratamento , Bibliometria , Ensaios Clínicos como Assunto/classificação , Projetos de Pesquisa , Ensaios Clínicos Controlados Aleatórios como Assunto/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...